Product Introduction
2. Control protocol support: Sony visca, pelco-p, PELCO-D optional
3. The camera supports the access of all kinds of domestic cameras connected to Hikvision ds-2zmn series movement and its protocol
4. Size: 50mm * 56mm
5. Middle positioning hole: 24 * 36, with an aperture of 2mm
Product Parameters
Table 1 Interface function introduction table |
||
Serial number |
Interface Name |
Description |
1 |
Power DC head |
12V power input |
2 |
Network Ports |
Network cable access port |
3 |
CN4 green port |
Audio output port |
4 |
CN3 red port |
Audio input port |
5 |
Grey end rows |
Pins 1-9 from left to right, see Table 2 for pin definitions |
6 |
36P terminal |
Connecting the movement |
7 |
9P terminal |
Pins 1-9 from left to right, see Table 3 for pin definitions |
8 |
J1 4P Network Interface |
Pins 1-4 from right to left, see Table 4 for pin definitions |
9 |
J3 8P Audio Alarm Interface |
Pins 1-8 from right to left, see Table 5 for pin definitions |
10 |
J2 6P Power 485 interface |
Pins 1-6 from left to right, see Table 6 for pin definitions |
Table2 Gray end rows |
||
Serial number |
Needle angle name |
Description |
1 |
VISIC-TXD |
|
2 |
VISIC-RXD |
|
3 |
485-TXD |
Camera serial port sending |
4 |
485-RXD |
Camera serial reception |
5 |
AHD |
AHD signal output |
6 |
ALM-OUT |
Alarm signaloutput |
7 |
ALM-IN |
Alarm signalinput |
8 |
CVBS |
CVB signal output |
9 |
GND |
Power Ground |
Table3 9P terminals |
||
Serial number |
Needle angle name |
Description |
1 |
485-RXD |
Camera serial reception |
2 |
485-TXD |
Camera serial portsending |
3 |
GND |
Power Ground |
4 |
DC12V |
Power supply 12V |
5 |
GND |
Power Ground |
6 |
CVBS-OUT |
CVB signal output |
7 |
GND |
Power Ground |
8 |
AHD |
AHD signal output |
9 |
GND |
Power Ground |
Table4 4P Network Interface |
||
Serial number |
Needle angle name |
Description |
1 |
TX+ |
|
2 |
TX- |
|
3 |
RX+ |
|
4 |
RX- |
|
Table5 J3 8P Audio Alarm Interface |
||
Serial number |
Needle angle name |
Description |
1 |
NC |
NC |
2 |
ALM-OUT |
Alarm signaloutput |
3 |
ALM-IN |
Alarm signalinput |
4 |
ALINE-IN |
Audio signal input |
5 |
ALINE-OUT |
Audio signal output |
6 |
Audio Interface Block |
Audio Interface Block |
7 |
CVBS-OUT |
CVB signal output |
8 |
GND |
Power Ground |
Table6 6P Power 485 Interface |
||
Serial number |
Needle angle name |
Description |
1 |
DC12V |
Power supply 12V |
2 |
GND |
Power Ground |
3 |
485-RXD |
Camera serial reception |
4 |
485-TXD |
Camera serial portsending |
5 |
VISIC-TXD |
|
6 |
VISIC-RXD |
|